Home Care Mattresses

Designed for reliable early pressure prevention and everyday comfort.
The E100 is a medium-firm foam mattress designed for simple, dependable comfort at home. Its triple-foam construction balances softness and stability, promoting natural posture and restful support throughout daily use. The breathable knit cover enhances airflow, helping maintain a cooler, drier surface for better skin comfort.

Elata E100 Foam Mattress | Single

$1,101.28
The E200 delivers adaptive comfort and reliable support in a design built for home care. Combining responsive pocket springs with layered foam, it moves naturally with the user while maintaining balanced postural stability. The breathable knit cover promotes airflow to keep the surface cool, dry, and comfortable across extended use.

Elata E200 Pocket Spring & Foam Mattress | Single

$1,223.78

Clinical Foam Mattress

Built for stage 1–2 pressure injury prevention and treatment.

Hybrid Mattress

A system that delivers smooth, responsive alternating care for the prevention and treatment of pressure injuries up to stage 4.
One mattress, two levels of care. The E400 is a hybrid mattress designed for adaptable pressure care. Used alone, it offers static foam and air support to help prevent and treat stage 2 injuries. With the addition of the EP10AU pump, it transitions seamlessly into dynamic alternating therapy, delivering effective treatment up to stage 4.

Elata E400 Hybrid Air-Foam Mattress |King Single

View Product
The E500 with the EP20AU pump brings together the familiar comfort of foam and the clinical precision of air therapy. This hybrid system delivers smooth, responsive alternating care for the prevention and treatment of pressure injuries up to stage 4, while cushioning sensitive users with consistent, pain-reducing support.

Elata E500 Alternating Hybrid Mattress |Single

View Product

Alternating Air Mattress

Designed for high to very high-risk patients requiring advanced dynamic pressure therapy. They support prevention and treatment up to stage 4 pressure injuries.
The E600 mattress is a full replacement surface designed for patients at very high risk of pressure injury. With 20 multi-layered air cells configured with a 1-in-2 alternating cell cycle and a static head section, it provides consistent weight redistribution and stable cranial support.

Elata E600 Alternating Air Mattress | Single

View Product
E700 is selected for the most complex pressure care scenarios, where advanced therapy and precise control are critical. Featuring a configurable 1-in-4 alternating air cell structure, it delivers deeper immersion and refined pressure redistribution for high-acuity environments.

Elata E700 Advanced Alternating Air (1-in-4 cells) Mattress | Single

View Product

FAQs

Are Elata Mattresses suitable for homecare & hospital care?

Yes. Elata offers dedicated solutions for homecare, aged care, rehabilitation, acute wards, and ICU environments. Each mattress is engineered to suit its intended care setting, from simple prevention to complex clinical treatment.

Home care - Mattresses E100 & E200

Entry level Clinical foam for pressure care - Mattress E300

Hybrid foam - Mattresses E400 & E500

Alternating air - Matresses E600 & E700

Which Elata Mattress is suitable for Stage 3 & 4 pressure injuries?

For Stage 3 and Stage 4 pressure injuries, Elata recommends advanced support surfaces that provide active pressure redistribution and clinical control.

  • E400 (with pump) – Suitable for higher-risk patients who require dynamic support with the flexibility of hybrid technology. Ideal where clinical needs are increasing but full air replacement may not yet be required.
  • E500 (Hybrid) – Designed for advanced pressure injury management. Combines foam stability with alternating air therapy, making it well suited to rehabilitation, palliative care, and complex aged care environments.
  • E600 (Full Alternating Air) – Appropriate for high-risk patients in acute care. Delivers consistent alternating air therapy with greater immersion and envelopment.
  • E700 (Advanced Alternating Air) – Recommended for very high-risk or clinically complex cases, including ICU, spinal and specialised care settings where maximum pressure redistribution and control are essential.

Selection should always be guided by clinical assessment, patient condition, mobility, tissue tolerance and care environment.

Can Elata Mattresses be upgraded as care needs change?

Yes. The Elata range is designed as one connected pressure care system that supports a step-up clinical pathway.

The E400 hybrid mattress can be upgraded from a static surface to dynamic alternating therapy by adding the compatible Elata EP10AU pump. This allows care teams to increase therapeutic support without replacing the entire mattress.

Beyond that, the broader Elata E100–E700 range is structured to move with the patient journey, from prevention and foam support through to hybrid systems and full alternating air therapy. As risk levels increase, clinicians can step up to higher-level surfaces within the same integrated platform.

One mattress range. Progressive levels of support.

How does the Elata Pump AdaptiveMode™ work?

Elata AdaptiveMode™ continuously analyses pressure data and senses meaningful patient movement. It automatically adjusts pressure levels and cycle timing in real time, transforming static intervals into responsive, personalised therapy without manual input.

The EP10AU operates within a 1-in-2 alternating air cycle, optimising pressure transitions between alternating cellgroup.

The EP20AU functions across both 1-in-2 and configurable 1-in-4 alternating cycles, delivering more precise pressure adjustments and enhanced immersion control.

What is the Elata TiltSense™ function, and when is it used?

Elata TiltSense™ is available with the EP20AU pump and detects changes in backrest elevation, automatically increasing pressure in key support zones to help prevent bottoming out. When the backrest lowers, therapy returns to its previous setting. It is ideal for patients who are frequently repositioned or seated upright.

How long does the Elata PowerGuard™ battery backup last?

Elata PowerGuard™ keeps the EP20AU pump delivering full alternating therapy for up to twelve hours during a power outage.

Once battery capacity is reduced, the system automatically transitions into Elata SafeHold™. In this protective low-power state, mattress pressures are stabilised and safely maintained without carer intervention, ensuring continued patient protection until power is restored.

How does Elata ID™ simplify setup?

Elata ID™ automatically recognises the connected mattress and selects the appropriate therapy mode. It removes guesswork, reduces setup time, and ensures the system runs at the correct configuration from the start.

Do Elata pumps require regular servicing?

Routine inspection and preventative servicing are recommended to maintain optimal performance. Elata pumps include built-in diagnostics to support early issue detection and reduce unexpected downtime.